8 | Water connection
80.06.083_iCombi Pro-iCombi Classic_IM_V01_en-US 61 / 84
8.2 Connecting the water inlet
The water inlet is located on the back or underside of the device.
Device size XS GN
Device size 6 half size GN to 10 full size GN
Device size 20 half size GN, 20 full size GN
a The on-site water supply line is flushed and vented.
a The water hose is flushed.
a Safety devices, such as check valves or CA system separators are installed in
the feed line on the tap.
a Line for shared cold water connection: 3/4inch
a Cold water temperature: max. 30°C [86°F]
a Water hardness: min. 5°dH (90ppm).
a Conductivity: min. 50 µS
a The chlorination (Cl
2
) is below 0.2 mg/l (0.2 ppm) and the chloride concen-
tration (Cl
-
) below 80 mg/l (80 ppm). If the values are higher, use a water
filter. Follow the instructions for selecting the water filter.
1. Connect the water hose to the water inlet for the device.
2. Open the tap.
>> The water inlet is connected.
Recommendation for CombiMaster Plus without care
The manufacturer recommends a preventive check approx. 6 months after com-
missioning to determine the current limescale build-up in the steam generator.
The inspection should be carried out by a trained technician.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus XS and is the answer not in the manual?

Rational CombiMaster Plus XS Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus XS
CategoryConvection Oven
LanguageEnglish

Related product manuals