8 | Water connection
80.06.083_iCombi Pro-iCombi Classic_IM_V01_en-US 61 / 84
8.2 Connecting the water inlet
The water inlet is located on the back or underside of the device.
Device size XS GN
Device size 6 half size GN to 10 full size GN
Device size 20 half size GN, 20 full size GN
a The on-site water supply line is flushed and vented.
a The water hose is flushed.
a Safety devices, such as check valves or CA system separators are installed in
the feed line on the tap.
a Line for shared cold water connection: 3/4inch
a Cold water temperature: max. 30°C [86°F]
a Water hardness: min. 5°dH (90ppm).
a Conductivity: min. 50 µS
a The chlorination (Cl
2
) is below 0.2 mg/l (0.2 ppm) and the chloride concen-
tration (Cl
-
) below 80 mg/l (80 ppm). If the values are higher, use a water
filter. Follow the instructions for selecting the water filter.
1. Connect the water hose to the water inlet for the device.
2. Open the tap.
>> The water inlet is connected.
Recommendation for CombiMaster Plus without care
The manufacturer recommends a preventive check approx. 6 months after com-
missioning to determine the current limescale build-up in the steam generator.
The inspection should be carried out by a trained technician.