10 | Gas connection for gas devices
70 / 84 80.06.083_iCombi Pro-iCombi Classic_IM_V01_en-US
Natural gas G20 USA
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Required connection
flow pressure (mbar)
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
Wobbe index (MJ/m³)
Wi
45.67 45.67 45.67 45.67 45.67 45.67
Wobbe index (MJ/m³)
Ws
50.72 50.72 50.72 50.72 50.72 50.72
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
48.58
ft³/h
104.64
ft³/h
82.21
ft³/h
149.48
ft³/h
156.96
ft³/h
298.96
ft³/h
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
49500
BTU/hr
106500
BTU/hr
83500
BTU/hr
152000
BTU/hr
159500
BTU/hr
303500
BTU/hr
Propane gas 3P G31 USA
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Required connection
flow pressure (mbar)
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
10-15
in/wc
Wobbe index (MJ/m³)
Wi
74.75 74.75 74.75 74.75 74.75 74.75
Wobbe index (MJ/m³)
Ws
81.19 81.19 81.19 81.19 81.19 81.19
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
2.23
lb/h
4.80
lb/h
3.77
lb/h
6.85
lb/h
7.19
lb/h
13.7
lb/h
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
48500
BTU/hr
104000
BTU/hr
82000
BTU/hr
148500
BTU/hr
156000
BTU/hr
296500
BTU/hr