ERVICE
S
44 6823346-R3
15 Allow the load rest for 5 seconds on the iForks. Press
and hold the "Zero" button for three seconds.
17 Press the "Total" button.
16 The screen will show "Adj08" and then will count down
from 8 while the display records the weight. The screen
will return to showing the weight and an arrow flashing
over "e2".
14 Place a Weight 2 on the pallet/cover so that the weight
is centered evenly between the four corner positions.
FK0271.eps
3.2-5 Weight Calibration (continued)
14
15
16
17
Weight 2