ROUBLESHOOTING
T
16 6823346-R3
2.4-4 Display
Problem
Solution
Disconnect the display from the system.
If the display remains unstable or does not
react to being disconnected, the board is
faulty.
If not, there may be a problem with the load
cell. Contact Cascade.
Check for moisture. Look for condensation or
water drops. Contact Cascade.
To determine if the display is faulty:
Change does not show on the display when
the load cells are disconnected.
The display remains unstable, even when not
load cell is connected
The display reacts when going over bumps
or other kinds of shock.
The display is unstable and
does not react to weights.
External Power Supply Equipped:
Check fuse and verify that an extra fuse is not
installed.
Battery Supply (equipped with four AA):
Check batteries. Replace with new batteries
(6 VDC) or rechargeable (4.8 VDC).
Display does not turn on
External Power Supply Equipped:
Check voltage. If voltage is below 11.8 VDC,
the converter or fuse may be damaged.
Replace the fuse.
If the fuse is not damage, contact Cascade.
Battery Supply (equipped with four AA):
Replace with new batteries (6 VDC) or
rechargeable (4.8 VDC)
Check parameter setting, parameter 62.
NOTE: The display may be set to shut off after
2 minutes from the factory.
Display automatically shuts
off after 2 minutes