ERVICE
S
22 6823346- R3
3.1-3 Parameter Table
Parameter
Number Function
Software
Version
Default Settings
Available Setting OptionsEU US
01 Weight units 1 2
1 = kg
2 = lb
02 Smallest graduation step for multirange 1 2 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50
03 Biggest graduation step for multirange 2 5 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50
04 Number of divisions for every range 1000 1000 0000 – 9999 divisions
05 Weighing capacity system (full scale) 2500 5000 0 – 99999
06 Motion Tolerance for stable 2 2 off, 0.5, 1, 2, 4, 8, 16, 32 grad./sec
07 Filter Size 8 8
off, 1-12 (Scale:1 light filtering, 12 high
filtering)
08 Auto zero range (zero track) 0.5 0.5 off, 0.5, 1, 3 grad./sec
09 Zero range positive (+) 10 10 0 – 100 percentage of span
10 Zero range negative (-) 10 10 0 – 100 percentage of span
11 Test function (display service mode) basic basic basic, count, res10
12 Power on – automatic zero no no yes, no
13 Approved/Non-approved version
A
none none none, ntep, oiml, ntepC
14 Sampling quantity 10 10 1, 2, 5, 10, 20, 50, 95
15 Units switch mode active yes yes no, yes
16 Setpoint function
B
0 0
0 = not used
1 = gross overload
2 = net overload
3 = fill manual tare
4 = fill auto tare
5 = gross overload not authorized to
change gross setting
6 = net overload not authorized to
change net setting
7 = gross overload delayed
8 = net overload delayed
9 = gross overload delay not
authorized to change gross setting
10 = net overload delay not authorized
to change net setting
11 = gross overload+errors
12 = gross overload+errors, no
changes allowed
13 = gross overload+errors, delayed
14 = gross overload+errors delayed,
no changes allowed
18 Gravity value working area 9.812 9.797 9.750 – 9.850
19 Print format date/time EU US
EU = dd/mm/yy
US = mm/dd/yy
A Some software versions may not offer "ntepC" as an option.
B Some software versions may only have options 1 through 10 available.