236823346-R3
ERVICE
S
3.1-3 Parameter Table (continued)
Parameter
Number Function
Software
Version
Default Settings
Available Setting OptionsEU US
28
Printout format for com1 and com2 2.15 & before
stnd stnd stnd, total, confi
Printout format for com2.1 A
2.18
29 Header lines added 0 0 0 – 3
30
Baudrate com2 2.15 & before
9600 9600 600, 1200, 2400, 4800, 9600, 19200
Baudrate com2.1 A
2.18
31
Setting com2 2.15 & before
8_n_1 8_n_1 8_n_1, 8_n_2, 7_n_1, 7_n_2
Setting com2.1 & 2.2 A
2.18
32
End Character com2.2 only A
2.18 cr cr cr, lf, crlf
34 End character com2 cr cr cr, lf, crlf
35 Protocol com2
B
0 0
0 = PC bi-directional NU
1 = PC Excel format on print command
2 = remote display
3 = printer protocol with power control
4 = printer protocol without power
control
5 = Not used
6 = PC Excel format with ack/nack
7 = Mobile barcode printer
8 = Scanner serial prot.
36 Number of linefeeds com2 4 4 0 – 9
37 Handshake com2 soft soft soft (Xon/Xoff), hard (CTS)
38 Print Twice
C
0 0
0 = Print only once
1 = Print twice
39
Protocal com2.2 only A
2.18 None None
None, 0 (PC bidirectional)
NOTE: This is automatically set based
on parameter 35 setting.
40 Level sensor no/ls no/ls no/ls, nc/ls, no/cs, ra/cs, ls
41 Delay trigger time level sensor 3 3 0 – 10 sec
43 Compensation factor correction factor 1 1 0.1 – 10.0
44 Compensation factor X-direction 1 1 0.1 – 10.0
45 Compensation factor Y-direction 1 1 0.1 – 10.0
49 Underload percentage of FS 002 002 0%-100%
60 Battery used 6 6 6V, 12V
61 Low Bat switch-off time 2 2 0 = never off, 1 – 99 minutes
62 Auto shut-off time indicator 2 2 0 = never off, 1 – 99 minutes
A NOTE: Com2.1 is used with a printer and Com2.2 is used for bluetooth communication to a PDA.
B Some software versions may only have options 1 through 5 available
C Some software versions may not offer this parameter.