EasyManua.ls Logo

Raymarine e7 - 9.4 Radar range and image quality

Raymarine e7
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Poweringtheradarscanneronandoff
Intheradarapplication:
1.SelectMenu.
2.SelectPowertoswitchtheRadarspowerOnandOff.
TheradarwillalwayspowerupinStandbymode.
3.SelectRadartoswitchtheradarbetweenTransmitandStandby
modes.
Usingthepowerbuttonandtouchtoswitchoperatingmodes
Theradaroperatingmodescanalsobesetusingthemultifunction
displayspowerbuttonmenu.
1.PressandreleasethePowerbutton
2.SelectStartRadarTXtostarttheradartransmitting.
3.SelectStopRadarTXtoputtheradarintostandby.
Usingthepowerbuttontoswitchoperatingmodes
Theradaroperatingmodescanalsobesetusingthemultifunction
displayspowerbuttonmenu.
1.PressandreleasethePowerbutton
2.PressthePowerbuttonagainsothatStartRadarTXis
highlighted.
WiththeDisplayBrightnessdialogopenpressingthePower
buttonwillswitchbetweenTransmitandStandby.
9.4Radarrangeandimagequality
Maximumradarrange
Theusablerangeoftheradarislimitedbyfactorssuchasthe
heightofthescanner,andheightofthetarget.
Maximumradarrangeisessentiallyline-of-sight,soislimitedby
theheightofthescannerandtheheightofthetargetasillustrated
below:
a
1
a
2
h
H
D16 43 -4
R
max
R
max
= 2.23 ( h + H )
1
3
2
ItemDescription
1Radarequippedvessel.
2
Curvatureoftheearth.
3
Target(Cliff).
a
1
Radarhorizonofantenna.
a
2
Radarhorizonoftarget.
R
max
Maximumradarrangeinnautical
miles.
R
max
=a
1
+a
2
hRadarantennaheightinmetres.
HTargetheightinmetres.
Usingradar
137

Table of Contents