MenuitemDescriptionOptions
BridgeNMEAHeading
IfsettoON,NMEAheadingdatawillbebridgedontotheSeaTalk
databus,andwillbesenttoallNMEA-connecteddevices.If
settoOFF,NMEAheadingdatawillNOTbebridgedontothe
SeaTalkbus.Anexampleofauseforthissettingiswhenusing
MARPAwithanexternalfastheadingsensor,inwhichcaseyou
shouldsetthisoptiontoOFFtoensurethatallNMEA-connected
unitsreceiveheadingdatafromtheexternalheadingsensor.
On
Off(default)
NMEAOutputSettings
AllowsyoutoenableordisabletheindividualNMEA“sentences”
thataresentbythemultifunctiondisplaytoanydevices
connectedtheNMEAoutputport.
APB
BWC
BWR
DBT
DPT
GGA
GLL
GSA
GSV
MTW
MWV
RMA
RMB
RMC
RSD
RTE
TTM