4.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetypeandlength
Unlessotherwisestateduseonlystandardcablesofthe
correcttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthecorrect
qualityandgauge.Forexample,longerpowercablerunsmay
requirelargerwiregaugestominimizevoltagedropalongthe
run.
Routingcables
Cablesmustberoutedcorrectly,tomaximizeperformanceand
prolongcablelife.
DoNOTbendcablesexcessively.Whereverpossible,ensure
aminimumbenddiameterof200mm(8in)/minimumbend
radiusof100mm(4in).
100 mm (4 in)
200 mm (8 in)
Protectallcablesfromphysicaldamageandexposuretoheat.
Usetrunkingorconduitwherepossible.DoNOTruncables
throughbilgesordoorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacingtwine.Coil
anyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposedbulkheador
deckhead,useasuitablewatertightfeed-through.
DoNOTruncablesneartoenginesoruorescentlights.
Alwaysroutedatacablesasfarawayaspossiblefrom:
otherequipmentandcables,
highcurrentcarryingacanddcpowerlines,
antennae.
Caution:Pullingcables
DoNOTusecordsorropes,attachedtocable
connectors,topullcablesthroughrestricted
apertures(e.g.asinbulkheads),asthiscould
causedamagetocables.
Strainrelief
Ensureadequatestrainreliefisprovided.Protectconnectors
fromstrainandensuretheywillnotpulloutunderextremesea
conditions.
Circuitisolation
Appropriatecircuitisolationisrequiredforinstallationsusing
bothACandDCcurrent:
Alwaysuseisolatingtransformersoraseparatepower-inverter
torunPC’s,processors,displaysandothersensitiveelectronic
instrumentsordevices.
AlwaysuseanisolatingtransformerwithWeatherFAXaudio
cables.
Alwaysuseanisolatedpowersupplywhenusinga3rdparty
audioamplier.
AlwaysuseanRS232/NMEAconverterwithopticalisolation
onthesignallines.
AlwaysmakesurethatPC’sorothersensitiveelectronic
deviceshaveadedicatedpowercircuit.
Cableshielding
Ensurethatalldatacablesareproperlyshieldedthatthe
cableshieldingisintact(e.g.hasn’tbeenscrapedoffbybeing
squeezedthroughatightarea).
4.2Connectionsoverview
Cableconnectorsareontherearoftheproduct.
D12 05 6-1
Theunithas2xSeaT alk
ng
connectors.
ConnectingSeaTalk
ng
cables
1.Rotatethelockingcollaronthebackoftheunittothe
UNLOCKEDposition.
2.Ensurethespurcableendconnectoriscorrectlyoriented.
3.Fullyinsertthecableconnector.
4.Rotatelockingcollarclockwise(2clicks)untilitsnapsinto
theLOCKEDposition.
24