RudderLimitsetting
AspartoftheDocksidecalibrationprocess,thesystemwill
set-uptherudderlimits.
•Forvesselswitharudderreferencetransducer—This
procedureestablishestherudderlimit.Therudderlimitwillbe
displayedwithamessageconrmingthattherudderlimithas
beenupdated.Thisvaluecanbechangedifrequired.
•Forvesselswithoutarudderreferencetransducer—a
defaultof30degreesisdisplayed,andcanbechangedas
required.
Checkingtherudderdrive
Aspartofthedocksidecalibrationprocess,thesystemwill
checkthedriveconnection.Onceithascompletedthecheck
successfully,amessagewillappearaskingifitissafeforthe
systemtotakethehelm.
Duringthisproceduretheautopilotwillmovetherudder.Ensure
itissafetoproceedbeforepressingOK.
Whenindocksidecalibrationmode,withtheMotorCheckpage
displayed:
1.Centreandletgooftherudder.
2.Disengageanyrudderdriveclutch.
3.SelectCONTINUE.
4.CheckitissafetoproceedbeforeselectingOK.
Forvesselswitharudderreferencetransducer,theautopilot
willnowautomaticallymovetheruddertoportandthen
starboard.
5.Forvesselswithoutarudderreferencetransducer,youwill
beaskedtoconrmthattherudderhasturnedtoportby
selectingYESorNO.
6.SelectOKifitissafetoengagetherudderintheopposite
direction.
7.Youwillbeaskedtoconrmtherudderturnedtostarboard
byselectingYESorNO.
8.Docksidecalibrationisnowcomplete,selectCONTINUE.
Note:Ifyouconrmeda“NO”responsefortherudder
movementtobothportandstarboard,thewizardwillexit.Itis
possiblethatthesteeringsystemdidnotmovetherudderin
anydirection,anditwillbenecessarytocheckthesteering
systembeforecompletingtheDocksidewizardprocedure
again.
YoucancancelDocksidecalibrationatanytimebypressing
STANDBY.
8.7Dealersettings
ThedocksidecalibrationwizardisonlyavailableonaSeaT alk
ng
system,forSeaT alksystemstheDealersettingsshouldbeset
beforegoingoutonthesea.
Thedealersettingsmenucanbeaccessedfrom:Mainmenu
>Setup>Autopilotcalibration>Dealersettings.Once
enteredthedealersettingsmenuwillcyclethroughallavailable
options.
Optionsandlimitsaredependentonthecoursecomputer
installed.
Commissioning-SPXandSmartPilotsystems
49