EasyManuals Logo

RDS Technology Weighlog 200 User Manual

RDS Technology Weighlog 200
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
OVERVIEW
6
2 The Control Switches
There are five switches on the front panel used individually or in combination
to programme, set, reset or select a function.
Channel Indicator
MANUAL WEIGHING
Press to manually
sample a weight (i.e.
alternative t
o a ref/dir.
Sensor)
Default setting = Off
ENTER /CLEAR
Pre
ss to add a bucket
weight to the channel
total.
HOLD to clear the
channel total. (If
configured, the
channel total is
automatically
printed).
Or
HOLD and power-on
to enter CAL Mode 1
ZERO BUCKET
WEIGHT
Press and hold for 3
beeps.
(Press again to
cancel)
Weigh empty
bucket then press
the REMOTE
ENTER button to
zero
Or
HOLD and power-
on to enter CAL
Mode 2
PRINTING
Channels 1-5
Press to print the
weight total for the
selected channel
Channel 6
Prints the weight
totals for channels
1-5 and the Grand
Total.
(Press ZERO to
cancel printing)
SELECT CHANNEL
Press and hold to
cycle through
channels 1-5 (sub
totals) and channel
6
(Grand Total)
Or
HOLD and power-on
to enter CAL Mode 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RDS Technology Weighlog 200 and is the answer not in the manual?

RDS Technology Weighlog 200 Specifications

General IconGeneral
BrandRDS Technology
ModelWeighlog 200
CategoryAccessories
LanguageEnglish