7 Troubleshooting
38 / 44 BAL_K21_EN_3V3_BLA_121-006423019
61 SSK aktive STA/DFA: The signal on the key-operated contact is permanently active.
Check the SSK switch and wiring/connections.
The response time for the error can be configured or the error message
can be disabled (see Parameter Miscellaneous Alarm display
Time activation).
62 BDE no priority W STA: The requested operating mode cannot currently be set because an op-
erating mode with a higher priority has been selected on one of the mechan-
ical controls (BDE-M, SURV, SURA, etc.).
DFA: The requested operating mode cannot currently be set because an op-
erating mode with a higher priority has been selected on one of the mechan-
ical controls (BDE-M).
For instance, if operating mode Locked has been set on the BDE-M, one
cannot change to Automatic with the BDE-D.
97 Maintenance time ex-
ceeded
W
R
The configured maintenance cycle has already been exceeded for a certain
time (>105%).
Inform our after-sales service centre urgently and have maintenance car-
ried out.
By acknowledging the warning message, the alarm is reset for 13 days.
98 Maintenance due W
R
95% of the configured maintenance cycle has been reached.
Inform our after-sales service centre and have maintenance carried out
soon.
The warning can be acknowledged. It will be displayed again when 100%
of the maintenance cycle has been reached.
101 Learning sensor W STA: The special door run for learning the sensors is being carried out.
Trigger several door openings until the message disappears.
111 Fire alarm External fire alarm / smoke removal contact is activated.
If false alarm, check contacts and connections.
112 Batt. not charged com-
plete
W STA: The battery is not completely charged.
Connect it to mains voltage.
The message disappears as soon as the battery is fully charged.
304 Sliding door open Sliding door is open.
Wait for sliding door to automatically close or push together manually.
305 VRR error
radial wing
Error when locking the radial protective sliding wing.
Press the “Locked” operating mode on the BDE-D again.
306 VRR error rotor Error when locking the rotation unit.
Press the “Locked” operating mode on the BDE-D again.
345 OP-VLS1 > 60s active Vertical forward sensor is activated for longer than 60 sec.
Check that no objects are activating the vertical forward sensor.
346 OP-VLS2 > 60s active Vertical forward sensor is activated for longer than 60 sec.
Check that no objects are activating the vertical forward sensor.
353 OP-VSSA > 60s active Vertical forward sensor is activated for longer than 60 sec.
Check that no objects are activating the vertical forward sensor.
354 OP-VSSI > 60s active Vertical forward sensor is activated for longer than 60 sec.
Check that no objects are activating the interior vertical sensor.