Introduction Warnings and Instructions
4
Warnings and Instructions
This section introduces the hazards and safety precautions associated with installing,
inspecting, maintaining or servicing this product. Before performing any task on this
product, read this safety information and the applicable sections in this manual, where
additional hazards and safety precautions for your task will be found. Fire, explosion,
electrical shock or pressure release could occur and cause damage to property,
environment, resulting in serious injury or death, if these safe service procedures are
not followed.
PRELIMINARY PRECAUTIONS
You are working in a potentially dangerous environment of flammable fuels, vapors,
and high voltage or pressures. Only trained or authorized individuals knowledgeable
in the related procedures should install, inspect, maintain or service this equipment.
Read The Manual
Read, understand and follow this manual and any other labels or related materials supplied with this equipment. If
you do not understand a procedure, call 1-800-323-1799 to locate a qualified technician. It is imperative to your
safety and the safety of others to understand the procedures before beginning work. Make sure your
employees and any service contractors read and follow the instructions.
Follow The Regulations
Applicable information is available in PEI/RP1100 Recommended Practices For The Storage And Dispensing Of
Diesel Exhaust Fluid (DEF)
1
, NFPA 70; National Electrical Code (NEC), Occupational Safety and Hazard
Association (OSHA) regulations and federal, state, and local codes. All these regulations must be followed. Failure
to install, inspect, maintain or service this equipment in accordance with these codes, regulations and standards
may lead to legal citations with penalties or affect the safe use and operation of the equipment.
ISO Standard For DEF
The production, handling and transportation of Diesel Exhaust Fluid (DEF) are governed by the ISO 22241
standard. Guidelines require manufacturers to follow clear procedures for the manufacture and distribution of DEF,
ensuring that the product meets the requirements of vehicle manufacturers. The ISO standards are available from
the ISO website
2
.
REQUIREMENTS FOR USE
Contractors MUST supply additional pressure relief in the DEF system downstream of
the check valve to assure the system does not exceed the recommended 50 psi during
thermal expansion!
Apply Loctite primer 7090 to all contractor assembled joints for additional residual
torque.
Application of the submersible DEF pump must be consistent with NFPA Code 70/NEC, OSHA regulations,
and federal, state and local fire codes, and other applicable local regulations.
The selection of any Veeder-Root product must be based upon physical specifications and limitations and the
product’s compatibility with the materials to be handled. Veeder-Root makes no warranty of fitness for a
particular purpose.
All Veeder-Root products should be used in accordance with applicable federal, state and local laws,
ordinances and regulations.
1. http://pei.org/PublicationsResources/RecommendedPracticesExams/RP1100/tabid/849/Default.aspx
2. http://www.iso.org/iso/search.htm?qt=22241&sort=rel&type=simple&published=on&active_tab=standards