MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
144 8540780 • 10/07/2020 • Rev.38
English
Frequency zero speed/Frequency1/ Frequency2: It shows
the maximum calculated frequency values fM and fm (fm is the
fM threshold frequency decreased by the hysteresis set). If the
displayed value is GREEN, the calculation of frequency gave a
positive result.
If the displayed value is RED, it is necessary to change the
parameters given in the following formulas.
1. rotational axis, rotational sensor. The frequency obtained
is:
v][pulses/resolutionRe
60
[rev/min]rpm
[Hz]f
2. Linear axis, rotational sensor. The frequency obtained is:
v][pulses/reRe
[mm/rev]*60
1000*[m/min]
[Hz] solution
pitch
speed
f
3. Linear axis, linear sensor. The frequency obtained is:
[µm/pulse]solutionRe
1000*[mm/s]speed
[Hz]f
4. Hysteresis. To be changed only if: fM=green; fm=red
KEY:
f = frequency
Rpm = rotational speed
Resolution = measurement
Speed = linear speed
Pitch = sensor pitch