MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
54 8540780 • 10/07/2020 • Rev.38
English
LED INDICATORS (Normal Operation)
Master M1 (Figure 16)
MEANING
LED
RUN
IN FAIL
EXT FAIL
COM
ENA
IN1÷8
OSSD1/2
CLEAR1/2
STATUS1/2
GREEN
RED
RED
ORANGE
BLUE
YELLOW
RED/GREEN
YELLOW
YELLOW
Power on - initial TEST
ON
ON
ON
ON
ON
ON
Red
ON
ON
MCM recognised
OFF
OFF
OFF
ON
(max 1s)
ON
(max 1s)
OFF
Red
OFF
OFF
Writing/loading/ diagram
to/from MCM card
OFF
OFF
OFF
5
flashes
5
flashes
OFF
Red
OFF
OFF
MSD requesting connection:
internal configuration not present
OFF
OFF
OFF
Flashes slowly
OFF
OFF
Red
OFF
OFF
MSD requesting connection:
(slave module or node number
not correct) (ref. System composition)
OFF
OFF
OFF
Flashes quickly
OFF
OFF
Red
OFF
OFF
MSD requesting connection:
(slave module missing or not ready)
(ref. System composition)
Flashes quickly
OFF
OFF
Flashes quickly
OFF
OFF
Red
OFF
OFF
MSD connected M1 stopped
OFF
OFF
OFF
ON
OFF
OFF
Red
OFF
OFF
Table 27 - Opening Screen
Table 28 - Dynamic Screen
Figure 16 - M1
MEANING
LED
RUN
IN FAIL
EXT FAIL
COM
IN1÷8
ENA
OSSD1/2
CLEAR1/2
STATUS1/2
GREEN
RED
RED
ORANGE
YELLOW
BLUE
RED/GREEN
YELLOW
YELLOW
NORMAL
OPERATION
ON
OFF
OFF
op. OK
ON = M1
connected to
PC
OFF=otherwise
INPUT condition
ON
MASTER_ENABLE1
and MASTER_ENABLE2
active
OFF
otherwise
RED with
output OFF
GREEN with
output ON
ON
waiting for
RESTART
Flashing
NO feedback
OUTPUT
condition
EXTERNAL
FAULT
DETECTED
ON
OFF
ON
incorrect
external
connection
detected
ON = M1
connected to
PC
OFF=otherwise
only the number
of the INPUT with
the incorrect
connection
flashes