MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
8540780 • 10/07/2020 • Rev.38 23
English
Module MO4L
TERMINAL
SIGNAL
TYPE
DESCRIPTION
OPERATION
1
24VDC
-
24VDC power supply
-
2
NODE_SEL0
-
Node selection
Input ("type B" according to
EN 61131-2 )
3
NODE_SEL1
-
Input ("type B" according to
EN 61131-2 )
4
0VDC
-
0VDC power supply
-
5
OSSD1
Output
Solid State Safety Output 1
PNP active high
6
OSSD2
Output
Solid State Safety Output 2
PNP active high
7
RESTART_FBK1/
STATUS1
Input/
Output
Feedback/Restart 1
Input according to EN 61131-2
SIL 1/PL c
PNP active high
8
RESTART_FBK2/
STATUS2
Input/
Output
Feedback/Restart 2
Input according to EN 61131-2
SIL 1/PL c
PNP active high
9
OSSD3
Output
Solid State Safety Output 3
PNP active high
10
OSSD4
Output
Solid State Safety Output 4
PNP active high
11
RESTART_FBK3/
STATUS3
Input/
Output
Feedback/Restart 3
Input according to EN 61131-2
SIL 1/PL c
PNP active high
12
RESTART_FBK4/
STATUS4
Input/
Output
Feedback/Restart 4
Input according to EN 61131-2
SIL 1/PL c
PNP active high
Table 11
The STATUS SIL 1/PL c signal outputs are shared with the feedback/restart inputs of
the OSSDs. To use them, the corresponding OSSD must be used with automatic reset
without external feedback monitoring.