MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
8540780 • 10/07/2020 • Rev.38 19
RESTORE function
If the M1 or M1S unit is damaged, you can replace it with a new one; having already saved
all the configurations on the MCM, all you need to do is insert the MCM in the new M1/M1S
and switch on the MOSAIC system, that will immediately load the backup configuration. In
this way, the work interruptions will be minimized.
Compatibility between MCM memory and Master modules:
M1S can load configurations from MCM if it is written by a M1S or M1
M1 can load configurations from MCM only if it is written by a M1
The LOAD and RESTORE functions can be disabled via SW. (see Figure 54)
Each time MCM is used, carefully check that the chosen configuration is the one that was
planned for that particular system. Try again a fully functional test of the system composed of
Mosaic plus all devices connected to it (see the "TESTING the system" section).