USER MANUAL SPREADER X-SERIES
14
RESQTEC Manual SPREADER X-series (DM064K08)
4.11. OPERATING THE PRODUCT
BEFORE STORING THE PRODUCT, IT IS RECOMMENDED TO DEPRESSURIZE THE CYLINDER. TO DO THIS, OPEN THE
ARMS WITH JUST A FEW MM BETWEEN THE SPREADER JAWS.
Connect a hydraulic hose to
the product and power unit.
Start the hydraulic power unit
(and open the valve).
Rotate the control handle
leftwards to open the arms.
Keep the handle leftwards.
Rotate the control handle
rightwards to close the arms.
Keep the handle rightwards.
1
2
3
4
See chapter 4.6. or 4.8.
Please refer to the power unit’s user manual for additional information.