EasyManua.ls Logo

REXROTH CS351 - Testing the Residual-Current-Operated Protective Device (RCD)

REXROTH CS351
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 609 929 B45/2013-06 |
CS351/CC-CS351 Bosch Rexroth AG 99
/108
Maintenance and repair
ENGLISH
9.2 Maintenance
Testing the residual-current-operated
protective device
Check the function of the residual-current-
operated protective device (RCD) by actuat-
ing the test button. Unless otherwise speci-
fied, we recommend performing this test
once a month, but at least every six months.
If the residual-current-operated protective
device has been triggered, the control volt-
age for the power and controller electronics
will be maintained. Only the main circuit will
be isolated.
1. Actuate the test button. The residual-cur-
rent-operated protective device must be
triggered (position “0”).
2. Switch the residual-current-operated pro-
tective device back on (position “1”).
Fig. 41: Testing the residual-current-operated
protective device
1 Test button for the residual-current-
operated protective device
The residual-current-operated
protective device is only avail-
able with the CS351E Compact
System for ErgoSpin hand-held
nutrunners.
NOTE
Damages to the compact system
Do not press the test button while
tightening.
If the residual-current-operated pro-
tective device has been triggered,
only switch it on again after the tight-
ening has been completed (abort by
the controller).
1
CS351_zweispaltig - D.book Seite 99 Dienstag, 16. Juli 2013 12:00 12

Related product manuals