nRF52832
www.szrfstar.com V1.3 - Sep., 2020
Shenzhen RF-star Technology Co., Ltd. Page 23 of 58
Return Value
AT+ECHO=[0,1]
OK
Remark
This command has two parameters:
0: Disable echo.
1: Enable echo.
AT+ECHO?
Function
Query serial port echo.
Example
AT+ECHO?
Return Value
AT+ECHO=0
OK
Remark
The current device is echo disabled.
AT+ECHO=
Function
Set serial port echo.
Example
AT+ECHO=1
Return Value
OK
Remark
Echo is enabled.
Take effect immediately, do not save after power off.
Device Status Display
AT+STATUS=?
Function
Query parameter range of this command.
Example
AT+STATUS=?
Return Value
AT+STATUS=[0,1]
OK
Remark
This command has two parameters:
0: Disable device status display.
1: Enable device status display.
AT+STATUS?
Function
Query the current display state of device status.
Example
AT+STATUS?
Return Value
AT+STATUS=1