nRF52832
www.szrfstar.com V1.3 - Sep., 2020
Shenzhen RF-star Technology Co., Ltd. Page 34 of 58
• Beacon
Query parameter range of this command.
AT+BEACON=<0-FFFF>,<0-FFFF>,<0-FFFF>,<-90-4>,<0-FF...>
OK
This command has five parameters:
Parameter 1: Company ID.
Parameter 2: Major UUID.
Parameter 3: Minor UUID.
Parameter 4: Reference RSSI at 1 m.
Parameter 5: User-defined UUID.
Query set parameters of Beacon.
AT+BEACON=0059,0102,0304,-50,0102030405060708090A0B0C0D0E0F10
OK
Set Beacon company ID: F1F2.
Set reference RSSI: -60.
Take effect after restart, save after power off.
Query parameter range of this command.
AT+POWER=[-40,-20,-16,-12,-8,-4,0,3,4]