nRF52832
www.szrfstar.com V1.3 - Sep., 2020
Shenzhen RF-star Technology Co., Ltd. Page 25 of 58
Remark
Enable device broadcast.
Non-connectable device.
Broadcast interval is 500 ms.
Take effect after restart, save after power off.
Connection Interval
AT+CNT_INTERVAL=?
Function
Query parameter range of this command.
Example
AT+CNT_INTERVAL=?
Return Value
AT+CNT_INTERVAL=[8-4000]
OK
Remark
The connection interval range is from 8 ms to 4000 ms.
AT+CNT_INTERVAL?
Function
Query the connection interval of the device.
Example
AT+CNT_INTERVAL?
Return Value
AT+CNT_INTERVAL=10
OK
Remark
The connection interval of the device is 10 ms.
AT+CNT_INTERVAL=
Function
Query device connection interval.
Example
AT+CNT_INTERVAL=20
Return Value
OK
Remark
The connection interval is set as 20 ms.
Take effect after restart, save after power off.
After the connection interval is set, it will only take effect when the device is initialized, which is
equivalent to restarting. The minimum connection interval between module and the mobile phone
APP is 20 ms (the minimum connection interval for Apple is 30 ms), and the connection interval
between modules can be less than 20 ms (minimum 8 ms). After the connection interval takes effect,
the connection interval will be coordinated according to different mobile phones, up to the "set
connection interval*3".