SERVICE PROGRAM MODE TABLES
B064 Series/B140 Series/G126 5-78 SM
011 Port 80 Enable
Controls if permission is given to get access to the SOAP
method over Port 80 on the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
5821* Remote Service Address Japan Only (B140 only)
001* CSS PI Device Code
Sets the PI device code. After you change this
setting, you must turn the machine off and on.
002* RCG IP Address
Sets the IP address of the RCG (Remote
Communication Gate) destination for call
processing at the remote service center.
[00000000h~FFFFFFFFh/1]
5824 NVRAM Data Upload
Uploads the NVRAM data to an IC flash memory card (B064) or an SD card
(B140). Push Execute.
Note: When uploading in this SP mode data, the front door must be open.
5825 NVRAM Data Download
Downloads data from an IC flash memory card (B064) or an SD card (B140) to
the NVRAM in the machine. After downloading is completed, remove the card
and turn the machine power off and on.