Service Menu
M199/M200/M203/M204 4-6 SM
LSU Adjustment
Input 160 bytes
setting.
Character: alphanumeric "0-9", "a-f", "A-F", only
valid data can be input.
Input length: 160 bytes
Trans. Belt Adjust
When you execute "Trans. Belt Adjust", the transfer belt adjustment is
done. This calibrates the motor speed to match the length of the new
transfer belt.
Fuser SC Detect On/Off*
If On, the engine detects SC559. If Off, the engine
does not detect "Fusing SC Reset".
Color
Registration
The engine will do color registration and density tuning automatically.
The printer will warm up automatically after this setting is changed.
Reset Transfer
Unit
Resets the transfer unit life counter.
Reset Fuser Unit Resets the fusing unit life counter.
Fuser SC Reset Resets the Fusing related SC.
Reset 2nd
Transfer unit
Resets the 2nd transfer unit (transfer roller) life counter.
Special Mode
DFU (Designed for Factory Use)
Do not change this setting.
Economy Color
Print
Tentative
Density
Sets the tentative density of each mode.
Text: 100 / 50 / 30 (Default: 100)
Image: 100 / 50 / 30 (Default: 50)
Graphic:100 / 50 / 30 (Default: 30)
Conversion
Mode
Sets the conversion mode for the economy color
print.
No: No conversion is executed.
Color Up Mode: Converts into economy color. The
image density is decreased.
B&W Up Mode: Converts into Economy Black and
white.
PM Parts Rep
Notice
Sets whether to display the PM parts replacement notice and whether
to stop the engine.
0 At near end: No Notice / Not Stopped