Vert.Dup.Back
Adjusts the vertical registration for the back side in duplex
mode. If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Reset Count Resets counters to factory defaults.
Clear Count Clears the Scanner and Jam Counters.
Replace Fuser
Resets the maintenance counter for the fusing unit..
This item appears only when the fusing unit life is almost expired or has expired.
Scan Maintenance
Mono Compression
Setting
Sets the monochrome compression type for scanning.
MH (Default)/ MR/ MMR
Regist Adjust
ADF Main Reg.
Adjusts the ADF Scan main-scan registration. (G181
doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
ADF Sub Reg.
Adjusts the ADF Scan sub-scan registration. (G181 doesn't
support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Flatbed Main Reg.
Adjusts the Flatbed Scan main-scan registration. (G181
doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Flatbed Sub Reg.
Adjusts the Flatbed Scan sub-scan registration. (G181
doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Size Adjust
ADF Main Reg.
Adjusts the ADF Scan main-scan magnification. (G181
doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
ADF Sub Reg.
Adjusts the ADF Scan sub-scan magnification. (G181
doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Flatbed Main Reg.
Adjusts the Flatbed Scan main-scan magnification. (G181
doesn't support this.)
5. Service Tables
144