BT (Busy Tone)
Detection
BT Setting
DFU
[Off/ On]
BT: Busy tone
BT Frequency
DFU
[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550
Hz/ 350-500 Hz/ 350-550 Hz/ 375-475 Hz/
380-520 Hz]
BT Level
DFU
[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB]
BT Cadence
DFU
[0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/
0.50/ 0.75]
Comm Settings
RTN Rate
The machine checks the actual data reconstruction errors
and then transmits an RTN depending on the decoding error
rate that is set by this setting (Number of lines containing an
error per page / Total number of lines per page).
[10%/ 15%]
V34 Modem
DFU
[Permitted (Default)/ Prohibited]
V17 Modem
DFU
[Permitted (Default)/ Prohibited]
V34 Settings
Equalizer
These selectors set the equalizer's training level to be
applied if training fails due to poor line connection.
[Automatic (Default)/ 4 Points/ 16 Points]
Redialing
Resend when a communication error occurs.
[Disabled (Default)/ Not Disabled]
First TX Speed
Sets the first transmission speed choice, before fallback.
[2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps
/ 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/
21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/
31200 Bps/ 33600 Bps (Default)]
5. Service Tables
148
5

Table of Contents