2-22
Confidential
Print Unable
E5
Turn the power off
and then back on
again.
An error occurred during access
to the DRAM in the main PCB
ASSY.
E500 2-39
Print Unable
E6
Turn the power off
and then back on
again.
Write error in the EEPROM of
the main PCB ASSY
E600 2-39
Print Unable
E7
Turn the power off
and then back on
again.
Read error in the flash ROM
E702 2-39
Print Unable
ZC
Turn the power off
and then back on
again.
Detected that supply power is
unstable. (less than 100 times)
6F00 2-33
Replace Drum -
Number of the drum unit
rotations has reached the upper
limit.
4200 2-28
Replace Toner -
Dot count or develop roller
counter of the toner cartridge
box is reaching the upper limit in
the continuous printing mode.
4D01 2-29
Open the Front
Cover, replace
Toner Cartridge.
Dot count or develop roller
counter of the toner cartridge
has reached the upper limit in
the toner stop mode.
4C01 2-29
Self-
Diagnostic
Turn the power off,
then on again.
Leave the machine
for 15 min.
Some fuser unit errors occurred
at power-ON or upon recovery
from sleep mode.
6901 2-32
Will Automatically
Restart within 15
minutes.
After the error was detected at
the fuser unit, power was turned
ON again and the error is being
checked. (If power is turned
OFF and ON after error code
6901 occurred, this code is
displayed for about 15 minutes.)
6902 2-32
Size Error Specify the correct
paper size for Tray
1.
For printing by feeding paper
from the paper tray, the size of
paper specified from the driver
set the size which was not
supported by the paper tray.
9702 2-38
Error message
Description
Error
codes
Refer
to:
Initial display Scroll