Loading...
RIGOL
© 2008 RIGOL Technologies, Inc. 2-57
Users Guide for DG10× 2 Series
Channel Coupling Settings
Press Utility Coupling, enter the following interface.
Figure 2-60
Channel Coupling Setting Interface
Table 2-24 Channel Coupling Setting Menu
Menu
Settings
Explanation
Switch
Coupling On
Coupling Off
Open or close the Coupling function
BaseCH
Channel_1
Channel_2
Choose CH1 or CH2 as the base source in
coupling
FreDev
PhaDev
Set the frequency deviation between the two
channels.
Set the phase deviation between the two
channels.
CopyCH
1 2
2 1
Copy the parameters from CH1 to CH2
Copy the parameters from CH2 to CH1
Save the setting and exit
Key Points:
1. Channel Coupling
(1) The coupling is only used for frequency and phase, as shown in the following
figure, the base channel will mark with a * sign on the screen. It indicates that
CH1 has coupling in the phase parameter.
Figure 2-61
Coupling Sign Instruction
Coupling Sign