InstallerProgramming
Page 106
LoopResponse
TheLoopResponsemenuenablesyoutosetthedifferenttimesfor
whichazoneviolationmustexistbeforethezonewilltriggeranalarm
condition
1) Normal:400ms(milliseconds).
2) Long:1second
3) Fast:10ms(milliseconds).
4) ExtraFast:1ms(millisecond).Thisloopresponse
isusuallyused
forshuttersorotherdevicesthatrequireveryquickresponses
Quick Keys Parameter Default Range
ZZ
ForcedArming
Thisoptionenablesordisablestheuseofforcedarmingforeachofthe
systemʹszones,asfollows:
1. Ifforcedarmingisenabledforaparticularzone,itallowsthesystem
tobearmedeventhoughthiszoneisfaulty.
2. Whenazone(s)enabledforforcedarmingisfaulted,theredLED
blinksduringthedisarmperiod.
3. Afterarming,allzonesenabledforforcedarmingarebypassedat
theendoftheexitdelaytimeperiod(p.70).
4. Ifafaultedzone(oneenabledforforcearming)issecuredduringthe
armedperiod,itwillno
longerbebypassedandwillbeincluded
amongthesystemʹsarmedzones
ZZ
PulsedCounter01
01‐15
Specifiesthatthezonewillcountthenumberofopenandclosepulses
received.Ifthezoneexceedsthepredefinednumberofpulses,thezone
willbetrippedandactaccordingtoitstypedefinition.Aftera25‐
secondtimeoutthepulsecounterisrestarted.Thepulselengthisthe
currentlydefinedloopresponsetimeperiod.(RefertoZones:Loop
Response,page106.)