 Testing
Thefollowingmenuisusedtoperformtestsonthesystem.Notethateachtestreferstothe
lasttimethedevicewasactivated.Testscanbeperformedonthefollowingelements:
Quick Keys Parameter Default Range

SelfTest
Thisfeatureprovidesanautomatedselftestforaselectedgroupof
localizedintrusionsensors(forexample,glassbreakdetectors,sound
discriminatorsandshocksensors)whichrespondtoanartificialsource
ofnoiseand/orvibration.
Automatedselftestingisespeciallyusefulwhensensorsareplacedin
highsecurityareaswherefailurecannotbetolerated.
Upto16zonescanbedesignatedforselftesting.
Asoundorvibrationgeneratorshouldbeusedthatcanbeplacedclose
enoughtothesensorstotriggerthemwhenthenoisesourceis
activated.AProgrammableOutputactsasthesourceofswitchedpower
forthenoise/vibrationgenerator(refertoSensorsTest,page127).Thisis
settoconformtothetestingschedule.Thescheduledefinesthetime
anddayforthefirsttest,andsetsthetimesforrepeatedtestsovera24
hourperiod.
AmessageissenttotheCentralStationifalltherelatedsensorsare
triggeredduringthetest(ifaReportCodehasbeendefined).With
successfulcompletionoftheselftest,anentryisalsoplacedinthe
system’sEventLog.
Ifoneormoreofthesensorsfailstotripduringthetestperiod,aself
testfailuremessageisgeneratedandsenttotheCentralStation.A
recordofthefailureisalsoenteredintheEventLog.

SoakTest
TheSoakTestfeatureisdesignedtoallowfalsealarmingforpredefined
detectorstobebypassedfromthesystem,whileanyalarmsgeneratedare
displayedtotheuserforreportingtotheMS.Thisisespeciallyusefulif
Policeresponsewithdrawalisbeingthreatenedandaparticularzoneis
causingunidentifiedproblems.
Upto8zonescanbeplacedonSoakTest.AnyzoneplacedintheSoak
Testlistisbypassedfromthesystemfor14daysandisautomatically
reinstatedafterthattimeifNOalarmshavebeengeneratedbyit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco LightSYS 2 Series and is the answer not in the manual?

Risco LightSYS 2 Series Specifications

General IconGeneral
Control Panel TypeHybrid
Operating Temperature-10°C to 55°C
Outputs4
CommunicationPSTN, GSM, IP
Wireless Frequency868MHz
ProgrammingVia keypad
Backup Battery12V, 7Ah
Remote ManagementYes
HumidityUp to 93% non-condensing