InstallerProgramming
Page 162
Quick Keys Parameter Default Range
Confirmation
TheconfirmationtimesrelatetotheZoneSequentialConfirmation
(AlarmConfirmation,see)
ConfirmStart(Confirm
delaytime)
000 1–120minutes
Specifiesthatthesystemcannotstartasequentialconfirmationprocess
untilthetimerhasexpired.Thistimestartswhenthesystemhassetand
willpreventconfirmedalarmsbeinggeneratedinsituationswhena
personhasbeenaccidentallylockedinthebuilding.
ConfirmTimeWindow
030 30–60minutes
Specifiesatimeperiodthatstartswhenanalarmistriggeredforthefirst
time.Ifasecondalarmistriggeredbeforetheendoftheconfirmation
timewindow,thesystemwillsendaconfirmedalarmtothemonitoring
station
ReportSplit
TheReportSplitmenucontainsparametersthatenabletheroutingof
specifiedeventstouptothreeMSreceivers.
MSArm/Disarm
1
st
backup2
nd
ReportsArming/Disarming(meaningClosings/Openings)eventstothe
MS
Donotcall(noreport).
Send1
st
:ReportsOpeningsandClosingstoMS1.
Send2
nd
:ReportsOpeningsandClosingsto MS2.
Send3
rd
:Rep o rtsOpeningsandClosingstoMS3.
Sendall:ReportsOpeningsandClosingstothealldefinedMS.
1
st
Backup2
nd
:ReportsOpeningsandClosingstoMS1.If
communicationisnotestablished,callsMS2.
1
st
Backup2
nd
3rd:ReportstoMS1.Ifcommunicationisnot
establishedcallsMS2.Ifcommunicationisnotestablishedagaincallsthe
MS.