Quick Keys Parameter Default Range
Confirmzones
Definewhichzonesaretobedefinedforalarmsequentialconfirmation.
Whenthefirstzonegoesintoalarmthesystemtransmitsthefirstzone
alarm.Whenthesecondzonegoesintoalarm,duringtheconfirmation
time,thepaneltransmitsthezonealarmandthepolicecode.
Notes:
Aconfirmedzonewillbepartofthesequentialconfirmationonlyifthe
partitioninwhichthealarmoccursisdefinedasconfirmedpartitionaswell.
AnyCodecanresetaconfirmedalarm.
Ifthefirstzoneisviolatedandnotrestoreduntiltheendofthe
confirmationtime(nosecondzonealarm),thanthiszonewillbeexcluded
fromtheconfirmationprocessuntilthenextarming.
CyclethroughtheeightzonesandtotoggleY/N
3 Outputs
TheUtilityOutputmenuprovidesaccesstosubmenusandtheirrelatedprogramming
parametersthatenableyoutochoosetheeventthatwilltriggeraselectedUtilityOutput,as
wellasthemannerinwhich
theoutputwillbeapplied.
AddingoneormoreUtilityOutputexpansionmodulestothesystemmakesanextensivelist
ofswitchedoutputpossibilitiesavailable.
AfteryouaccesstheUtilityOutputmenufromthemainInstallerProgrammingmenu,as
describedinthissection,youcanaccessthefollowingsubmenus:
Nothing,page126
System,page126
Partition,page128
Zone,page134
Code,page135