Page 125
Quick Keys Parameter Default Range

Confirmzones
Definewhichzonesaretobedefinedforalarmsequentialconfirmation.
Whenthefirstzonegoesintoalarmthesystemtransmitsthefirstzone
alarm.Whenthesecondzonegoesintoalarm,duringtheconfirmation
time,thepaneltransmitsthezonealarmandthepolicecode.
Notes:
Aconfirmedzonewillbepartofthesequentialconfirmationonlyifthe
partitioninwhichthealarmoccursisdefinedasconfirmedpartitionaswell.
AnyCodecanresetaconfirmedalarm.
Ifthefirstzoneisviolatedandnotrestoreduntiltheendofthe
confirmationtime(nosecondzonealarm),thanthiszonewillbeexcluded
fromtheconfirmationprocessuntilthenextarming.
CyclethroughtheeightzonesandtotoggleY/N
3 Outputs
TheUtilityOutputmenuprovidesaccesstosubmenusandtheirrelatedprogramming
parametersthatenableyoutochoosetheeventthatwilltriggeraselectedUtilityOutput,as
wellasthemannerinwhich
theoutputwillbeapplied.
AddingoneormoreUtilityOutputexpansionmodulestothesystemmakesanextensivelist
ofswitchedoutputpossibilitiesavailable.
AfteryouaccesstheUtilityOutputmenufromthemainInstallerProgrammingmenu,as
describedinthissection,youcanaccessthefollowingsubmenus:
Nothing,page126
System,page126
Partition,page128
Zone,page134
Code,page135

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco LightSYS 2 Series and is the answer not in the manual?

Risco LightSYS 2 Series Specifications

General IconGeneral
Control Panel TypeHybrid
Operating Temperature-10°C to 55°C
Outputs4
CommunicationPSTN, GSM, IP
Wireless Frequency868MHz
ProgrammingVia keypad
Backup Battery12V, 7Ah
Remote ManagementYes
HumidityUp to 93% non-condensing