InstallerProgramming
Page 160
Quick Keys Parameter Default Range

RandomMSTesting
No Yes/No
Yes:Atpowerupthepanelwillrandomsetatesttimebetween00:00
and23:59.Oncethehourisset,thiswillbethefixedreporthourofthis
panel.ThetimecanbeviewedunderthePeriodictesttimerfields
().Theintervalofsendingthetestwillbeasdefinedunderthe
PeriodicTesttimer
No:TheperiodictestwillbeaccordingtothetimedefinedundertheMS
periodictimer(
).

Parameters
AllowstoprogramparametersrelatedtooperationwiththeMonitoring
Station

MSRetries
08 01–15
ThenumberoftimestheLightSYS2redialstheMSafterfailingto
establishcommunication.

AlarmRestore
SpecifiesunderwhatconditionsanAlarmRestoralisreported.This
optioninformstheMSofachangeinthespecifiedcondition(s)duringan
alarmrestore.ThesereportsneedavalidReportCode.
ON BTO(BellTimeOut)Reportsth e restoralaft er theaudible
alarmtimesou t.
FOLLOW ZONE Reportstherestoralwhenthe zoneinwhichthe
alarmoccursreturnstoitsnonviolated(secured)state.
AT DISARMReportsth e restoralwhenth esystem(orthepartition
inwhichthealarmoccurs)isdisarmed,evenifthesirenhasalready
timedout .

M
STimers
Allowstoprogramtimersrelatedtooperationwiththemonitoring
station

PeriodicTest
ThePeriodicTestenablesyoutosetthetimeperiodthatthesystemwill
automaticallyestablishcommunicationtothemonitoringstationinorder
tochecktheconnection.Theperiodictestinvolvessendingtheaccount
numberandavalidtestreportcode(ContactID602,SIATX).Setthetest
timeand
dailyintervalforPeriodicTestReporting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco LightSYS 2 Series and is the answer not in the manual?

Risco LightSYS 2 Series Specifications

General IconGeneral
Control Panel TypeHybrid
Operating Temperature-10°C to 55°C
Outputs4
CommunicationPSTN, GSM, IP
Wireless Frequency868MHz
ProgrammingVia keypad
Backup Battery12V, 7Ah
Remote ManagementYes
HumidityUp to 93% non-condensing

Related product manuals