Quick Keys Parameter Default Range

LowRSSIGSM
Duration
1minute 001–255minutes
Theperiodlengthduringwhichthereceptionisbelowtheminimum
threshold(definedbytheGSMNetworkSensitivityparameter)that
triggersthePaneltosendareportofGSMLost.
( )

GSMNetworkLoss
10minutes 001–255minutes
TheperiodlengthafterwhichthePanelwillsendareportofGSM
networklosstotheMS.

SIMExpire
0months 00–36months
AprepaidSIMcardhasadefinedlifelengthdefinedbytheprovider.
AftereachchargingoftheSIM,theuserwillhavetomanuallyresetthe
expirationtimeoftheSIMcard.Thirtydaysbeforetheexpiringdate,a
notificationwillbedisplayedonthekeypad’sLCD.
Setthe
SIMexpiringdate(inmonths)usingthenumerickeys,according
tothetimegivenbytheprovider.

MSPolling
00000 065535times
Thetimeperiodthatthesystemwillestablishautomaticcommunication
(polling)withtheMSoverGPRS,inordertochecktheconnection.
3pollingtimescanbedefined:Primary,SecondaryandBackup.Foreach
timeperioddefinethenumberofunitsbetween1‐65535.Eachunit
representsatimeframeof
10seconds.
Note:
WhenusingthepollingfeaturethroughGPRSthe MSchannelparameter
mustbedefinedasGPRSonly.
ThereportcodeforMSpollingis999(ContactID)orZZ(SIA)
WhentheGPRSPrimarypollingtimeisdefinedas0,nopollingmessage
issenttotheMS
TheuseofthesetimeperiodsdependsonthereportingordertotheMS
definedbytheReportSplitMSUrgentparameter(See:5)Communication
> 2)MS > 7)Report Split)
ThefollowingtabledescribeshowthethreeMSsusetheprimary,
secondaryandbackuptimeintervalsinthevariousMSreport
split
options.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco LightSYS 2 Series and is the answer not in the manual?

Risco LightSYS 2 Series Specifications

General IconGeneral
Control Panel TypeHybrid
Operating Temperature-10°C to 55°C
Outputs4
CommunicationPSTN, GSM, IP
Wireless Frequency868MHz
ProgrammingVia keypad
Backup Battery12V, 7Ah
Remote ManagementYes
HumidityUp to 93% non-condensing