Quick Keys Parameter Default Range
(polling)withtheMSovertheIPnetwork,inordertocheckthe
connection.Threepollingtimescanbedefined:primary,secondaryand
b
ackup.Foreachtimeperiod,definethenumberofunitsbetween1–
65535.Eachunitrepresentsatimeframeof10seconds.
Note:
WhenusingthepollingfeaturethroughIP,theMSchannelparameter
mustbedefinedasIPonly.
TheuseofthesetimeperiodsdependsonthereportingordertotheMS
definedbythereportsplitMSurgentparameter(Seepage163).The
followingtabledescribeshowthethreeMSsusetheprimary,secondary
andbackuptimeintervalsinthevariousMS
reportsplitoptions.)
MS report
Urgent
events
MS 1 Polling
State
MS 2Polling
State
MS 3 Polling
State
Donotcall
N/A N/A N/A
Call1
st
Primary N/A N/A
Call2
nd
N/A Primary N/A
Call3
rd
N/A N/A Primary
CallAll Primary Primary Primary
1
st
Backup2
nd
Primary If(MS1isOK)
Secondary
else(MS#1
Fails)Backup
N/A
1
st
Backup
2
nd
3rd
Primary
If(MS#1isOK)
Secondary
else(MS#1
Fails)
Backup
If(MS#2isOK)
Secondary
else(MS#2
Fails)
Backup
1
st
Backup3
rd
Call2
nd
Primary Primary
If(MS#1isOK)
Secondary
else(MS#1Fails)
Backup
2
nd
Backup3
rd
Call1
st
Primary Primary
If(MS#2isOK)
Secondary
else(MS#2Fails)
Backup

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco LightSYS 2 Series and is the answer not in the manual?

Risco LightSYS 2 Series Specifications

General IconGeneral
Control Panel TypeHybrid
Operating Temperature-10°C to 55°C
Outputs4
CommunicationPSTN, GSM, IP
Wireless Frequency868MHz
ProgrammingVia keypad
Backup Battery12V, 7Ah
Remote ManagementYes
HumidityUp to 93% non-condensing

Related product manuals