Quick Keys Parameter Default Range
ProximityAntiMask
=Tamper
No Yes/No
Usedtodeterminetheoperationoftheproximityantimaskingdetection
indicatedbytheMWchannelintheWatchOUTDTdetector.
YES:Proximityantimaskdetectionwillactivatethetamperalarm.
NO:Proximityantimaskdetectionwillberegardedasafaultevent.
NotethatProximityAMoperatesforapproximately
2.2secondswhen
thedetectorisapproachedincloseproximity.
EnsurethatProxAntiMaskhasbeenenabledwhenconfiguringthe
WatchOUTDTbuszoneparameters.
AudibleProximityTamper
No Yes/No
Thisparameterrelatestothebussiren.
YES:Aproximityantiapproachviolationwillactivatethesiren.
NO:Aproximityantiapproachviolationwillnotactivatethesirenand
willberegardedastroublebythesystem.
SirenAuxiliary=Tamper
No Yes/No
Thisparameterrelatestothebussiren.
YES:Asirenauxiliarytroublewillberegardedastamperalarmbythe
system.
NO:Asirenauxiliarytroublewillberegardedastroublebythesystem.
RFWake‐Up
No Yes/No
Determineswhetherthesystemcanwakethe2‐waykeypadupduring
exit/entrytimesorwhenfailingtosetthesystem.
YES:Thesystemwakesthekeypad.
NO:Thesystemcannotwakeupa2‐waykeypad.Usethisoptiontosave