16 ProSYS Quick Programming Setup
3. Using the numeric keys, select a zone number whose designation (x:yy) is equivalent to
the one defined for the BUS detector. (The x represents the BUS Zone Expander ID
number and the yy represents the BUS detector ID number as set by the detector's ID
Dipswitches).
Press
to access the Partitions category.
4. Define Partitions, Groups, Zone Type and Zone Sound.
5. In the Termination category select a BUS Zone and press
.
6. Press
. Define a label and press to confirm.
7. Repeat steps 3-7 for all required BUS zones.
Step 3: Setting the BUS Detectors Parameters
1. From the main Installer menu select [2] Zones > [0] Miscellaneous > [3] BUS Zone
Parameters.
2. Select the zone number that the BUS Zone was assigned to and press
.
3. Configure the parameters for the relevant BUS detector.
Programming the Input on the iWISE BUS Detector
The iWISE BUS detectors have additional input on board.
1. Add iWISE BUS detector to the system as described in the Programming BUS Detectors
section.
2. From the main installer menu press [2] to enter the Zones menu.
3. Using the
/ keys, select [ONE BY ONE] and press .
4. Using the numeric keys, enter the desired zone number and press
.
Note:
You can select any zone number that is not defined on a Wireless Zone Expander or a BUS Zone
Expander.
5. Press to access the Partitions category.
6. Define Partitions, Groups, Zone Type and Zone Sound.
7. In the Termination category select one of the following options: BUS Zone Input N/C,
BUS Zone Input EOL, BUS Zone Input DEOL, BUS Zone Input N/O, BUS Zone Input
TEOL. Press
.
8. Press
. Select the BUS zone that the input zone belongs to. The Type field will be
updated automatically when selecting the zone.
9. Press
. Define the loop response time.
10. Press
, assign a label and press .
11. Repeat steps 3-10 for all required iWISE inputs.
Note for iWISE BUS Detectors:
The iWISE BUS detectors have additional input. The parameters of this input are the same as any other
regular wired zone in the system, with the exception that this input should be linked to one of the zones in
the system. For further information refer to instructions supplied with the product.