14 ProSYS Quick Programming Setup
ZONE TERMINATION (Only applicable for hard wired zones)
7. Using the
/ keys, select the required zone termination type and press
.
ZONE RESPONSE
8. Using the / keys, select the required response time and press .
ZONE LABELS (Zone description text)
QUICK KEYS = [2][8]
9. Using the / keys, select [LABEL] and press .
10. Using the numeric keys, enter the desired zone number and press
.
11. Using the keys listed below, enter the required text for the zone description and press
. (See page 10 for entering text descriptions.)
12. Repeat steps 10 and 11 for all zones requiring description text.
Programming BUS Detectors
The following section describes the flow of adding BUS detectors to the ProSYS. BUS detectors
can be programmed to the main unit or to a BUS zone expander.
Programming BUS detectors on the Main BUS
Step 1: Adding BUS Detector to the Main Unit
QUICK KEYS = [7][1][9][5]:
Note:
If you have already performed Auto Settings skip to Step 2 below: Assign BUS Detectors to a Zone ID and
set basic parameters.
1. From the main installer menu press [7][1][9][5] to access the BUS Zone category.
2. Using the
/ keys select a BUS detector ID number as set by the detector's
Dipswitches (01-32)
Note:
The bottom line in the display shows "(0:yy) Type: None". In the 0:yy designation, the 0 represents
that the BUS detector is on the main unit and is not assigned to a BUS Zone Expander. The yy
represents the BUS detector ID number (up to 32) as set by the detector's DIP switches.
3. Using the / keys move to the Type field. Use the key to select the
detector's type.
4. Repeat steps 2 and 3 for other BUS detectors.
Note:
If required you can add virtual zones to the system. Virtual zones are cost effective. They enable to use up
to 32 BUS Zones on the main unit without adding physical zone expanders. To add a Virtual BUS zone
expander select type VBZ08 or VBZ16 when adding a zone expander (Quick key [7][1][2]).
Step 2: Assign BUS Detectors to a Zone ID and set basic parameters
Each BUS zone detector should be assigned to a zone. BUS zones on the main unit can be
assigned to a virtual zone or to a physical wired zone. They cannot be assigned to wireless
zones or zones located on a BUS zone expander
1. From the main installer menu press [2] to enter the Zones menu.
2. Using the
/ keys, select [ONE BY ONE] and press .

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS and is the answer not in the manual?

Risco ProSYS Specifications

General IconGeneral
Wireless ZonesUp to 120
CommunicationPSTN, GSM, IP
ProgrammingKeypad, PC
Battery Backup12V/7Ah
Operating Temperature-10°C to +55°C