26 ProSYS Quick Programming Setup
Technical Specifications
Main
Input Power:
16.5VAC 40VA by an external class 2 listed AC/AC adapter)
Current Consumption:
60 mA, typical / 70 mA, maximum
Notes:
1. For US installations, use a listed AC/AC adapter 120VAC 60 Hz, to 16.5VAC 40VA.
2. The main unit current consumption does not include the Aux and the Battery charge.
Rechargeable Standby
Battery:
12 Volts up to 17.2 Amp-Hours (AH), typical
Power Outputs: Auxiliary Power: 12 Volts DC @ 600 mA, maximum (from all AUX
terminals)
Bell/LS (External): 12 Volts DC @ 900 mA, maximum (For UL
installation 300mA maximum)
Programmable Voltage: UO1: Relay (programmable output) (24V, 3 Amps)
UO2: 12V 500 mA transistor
UO3-UO6: Open Collector Active Pull-Down, 70 mA, max
8 LED Keypad (Not UL Listed)
Current Consumption:
13.8VDC +/-10%; 75 mA maximum
16 LED Keypad (Not UL Listed)
Current Consumption:
13.8VDC +/-10%; 75 mA maximum
LCD Keypad
Current Consumption:
13.8VDC +/-10%; 100 mA maximum
Proximity LCD Keypad
Current Consumption:
13.8VDC +/-10%; 250 mA maximum
Touchscreen Keypad
Current Consumption:
13.8VDC +/-10%; 30 mA typical / 180 mA maximum
Touchscreen Keypad with Proximity
Current Consumption:
13.8VDC +/-10%; 30 mA typical / 280 mA maximum
8 zone expansion module
Current Consumption:
13.8VDC +/-10%; 25 mA, typical / 30 mA, maximum
16 zone expansion module
Current Consumption:
13.8VDC +/-10%; 27 mA, typical / 45 mA, maximum
BUS Zone Expansion
Current Consumption:
13.8VDC +/-10%; 20 mA, typical
8,16 wireless zone expansion module (Not UL Listed)
Current Consumption:
13.8VDC +/-10%; 40 mA maximum
Frequency:
868.6-868.7 MHz (narrowband operation in EU) or 433.92 MHz
4 relay output expansion module
Current Consumption:
13.8VDC +/-10%; 25 mA typical / 160 mA maximum
Contacts:
4 Form C (SPDT) Relays.
Contact rating:
5 A / 24V DC
8 transistor output expansion module
Current Consumption:
13.8VDC +/-10%; 25 mA typical / 40 mA maximum
Contacts:
Open Collector, Active Pull-Down, 70 mA maximum
1.5A Power Supply Expansion Module (Not UL Listed)
Input Power:
16.5 Volts AC @ 40 VA (via transformer)
Current Consumption:
180 mA maximum
Rechargeable Standby
Battery:
12 Volts up to 17 Amp-Hours (AH), typical
Power Outputs:
Auxiliary Power: 12 Volts DC @ up to 1.5A*
Bell/LS (External) Sounder Output:12 Volts DC @ 900 mA, maximum
*: Total current Bell+Aux=1.5A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS and is the answer not in the manual?

Risco ProSYS Specifications

General IconGeneral
Wireless ZonesUp to 120
CommunicationPSTN, GSM, IP
ProgrammingKeypad, PC
Battery Backup12V/7Ah
Operating Temperature-10°C to +55°C
System TypeHybrid