14 - TROUBLESHOOTING403
14.2 PROPULSION ENGINES
For further information, please contact the RIVA Service Department.
Problem Cause Corrective action
1. Engine does not turn when starter is actuated
Battery
Starter
Engine wiring
LOP Local Operation Panel
ECU Engine Control Unit
Engine
Start-interlock limit switch
Low or defective
Cable connections defective
Engine wiring or starter defective
Faulty
Loose seating of assemblies or connectors
Loose plug-in connections
Gear locked (engine cannot start manually)
Limit switch not installed or defective
Wiring defective
Charge or replace
(see Manufacturer’s documentation)
Check that cable connections are properly se-
cured (see Manufacturer’s documentation)
Check that cable connections are properly se-
cured, contact Service
Contact Service Department
Visual inspection
Check plug-in connections
Contact Service Department
Check limit switch
Check wiring
2. Engine turns but does not re
Starter
Engine wiring
Fuel system
ECU Engine Control Unit
Poor or defective starter rotation
Faulty
Not vented
Faulty
Charge or replace battery
(see Manufacturer’s documentation)
Contact Service Department
Check vent
Contact Service Department