EasyManua.ls Logo

Riva 90 ARGO - Notes and Precautions; Maintenance

Riva 90 ARGO
436 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 - SAFETY DEVICES AND EQUIPMENT47
3.3.7 Portablere-extinguishersmaintenance
Component Maintenance Notes and precautions
Portable re extinguishers Checks and tests Check the state of charge of each re extinguisher at least once every 12 months, and in any
case before each journey at sea, by means of the installed pressure gauge. The re extinguish-
er is correctly charged when the weight value is as stated on the re extinguisher’s tag, and the
charge indicator on the pressure gauge is in the green area.
If they are found to be discharged or insufciently charged, or at least every 10 years, have
qualied technicians:
Check the condition of the container (cylinder);
Rell the extinguishing medium;
Carry out a hydrostatic test.
Have re extinguishers recharged even after partial use.
MAINTENANCE
At least every 12 months, and, in any case, before each journey to sea, check the state of
charge of the re extinguisher.
At least every 10 years, and in any case before each journey to sea, check the external state
of the re extinguisher.
At least every 6 months check the fastening of the re extinguisher.

Table of Contents