EasyManua.ls Logo

Riva 90 ARGO - Page 430

Riva 90 ARGO
436 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 - TROUBLESHOOTING 424
Problem Cause Corrective action
6. Temperature too high • The pump is working at a higher pressure than
permitted
• Faulty or worn pump which causes an internal
blow-by
• Excessive blow-by through valves and cylinder
• Oil too viscous
• Continuous overloaded operation
• Temperature too high in the room where the
pump unit is placed
• Check
• Check
• Check
• Check
• Check
• Check
7. Leaks from the seals • Possible abrasive substances have entered
into the oil circulation, damaging the pump’s
shaft
• Seals are faulty, broken or mounted in a wrong
way
• Too hot oil
• Check
• Check
• Check
8. Pump overcharging the motor • Too viscous oil
• Obstructed delivery line or excessive resist-
ance
• Check
• Check

Table of Contents