RS-LiDAR-16 User Manual
3.2 Accuracy
Figure 2: The Relation between accuracy and distance of target object.
3
The measurement target of accuracy is a 50% NIST Diffuse Reflectance Calibration Targets, the test performance is depending on
circumstance factors, not only temperature, range and reflectivity but also including other uncontrollable factors.
4
The test performance of power consumption is depending on circumstance factors, not only temperature, range and reflectivity but
also including other uncontrollable factors.
5
Device operating temperature is depending on circumstance, including but not limited to ambient lighting, air flow and pressure
etc.
Mechanical/
Electrical/
Operational
Power Consumption:12 W (typical)
4
Operating Voltage: 9-32 VDC (with Interface Box and Regulated
Power Supply)
Weight: 0.87 Kg (without cable)
Dimensions: 109 mm Diameter X 80.7 mm Height
Environmental Protection: IP67
Operation Temperature: -30 ℃ to +60 ℃
5
Storage Temperature: -40 ℃ to +85 ℃