5 OPERATION
5.1 Starting procedure
NOTE : This procedure must be carried out in the first start-up of SENTINEL, after every
upgrade of the SMART KEY and after every STOP action.
Make sure that all the SENTINEL connections are set up following the instructions of the paragraph 4
Insert the SMART KEY (see fig. 2 page 27).
Keep the starting panel and SENTINEL under tension.
SENTINEL carries out the AUTOTEST procedure following the bottom points:
1) The three led LED1, LED2 and LED3 switch on
2) The DISPLAY light up
3) After 2 seconds the DISPLAY visualizes the blower serial number memorized into the SMART KEY
WARNING : If the visualized number NOT corresponds to the blower serial number keep out
the tension from the starting panel and contact ROBUSCHI or an authorized distributor.
4) If the visualized number corresponds to the blower serial number, press ENTER, the DISPLAY visualizes
the following message during 2 sec..
5) Starts the electric motor, the led LED2 and LED3 switch off and the DISPLAY visualizes the following
message
6) From this moment it is possible to start the blower
S/N : XXYYYYY
ENTER ?
Robuschi S.p.A.
Parma Italy
P1=
-
XXX
XmBar
P2=+YYYYmBar