EasyManuals Logo

Rockwell Automation Allen-Bradley Kinetix 5500 Series User Manual

Rockwell Automation Allen-Bradley Kinetix 5500 Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014 183
Kinetix 5500 Safe Torque-off - Integrated Safety Chapter 10
When you issue a motion direct command to an axis to produce torque in
Program mode, for example MSO or MDS, with the safety connection present to
the drive, a warning message is presented before the motion direct command is
executed, as shown in Figure 77
.
Figure 77 - STO Bypass Prompt When the Safety Controller is in Program Mode
The warning in Figure 77 is displayed the first time a motion direct command is
issued.
After you acknowledge the warning message by clicking Yes, torque is permitted
by the drive and a warning message is indicated in the software as shown in
Figure 78
. Safety state = Not Running (torque permitted), Axis state = Stopped/
Running, Persistent Warning = Safe Torque Off Bypassed.
Figure 78 - Safety State Indications After Controller Transitions to Program Mode
(MDC executing)
IMPORTANT
Switch the controller to Run mode to exit Motion Direct Command mode
with STO function bypassed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Kinetix 5500 Series and is the answer not in the manual?

Rockwell Automation Allen-Bradley Kinetix 5500 Series Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Kinetix 5500 Series
CategoryServo Drives
LanguageEnglish

Related product manuals