Programming and Parameters 1-23
SPEED COMMAND
Spd Mode & Limits
084
085
086
[Skip Frequency 1]
[Skip Frequency 2]
[Skip Frequency 3]
Sets a frequency at which the drive will
not operate. [Skip Frequency 1-3] and
[Skip Frequency Band] must not equal 0.
Default:
Default:
Default:
Min/Max:
Units:
0.0 Hz
0.0 Hz
0.0 Hz
–/+[Maximum Speed]
0.1 Hz
087
087 [Skip Freq Band]
Determines the bandwidth around a skip
frequency. [Skip Freq Band] is split,
applying 1/2 above and 1/2 below the
actual skip frequency. The same
bandwidth applies to all skip frequencies.
Default:
Min/Max:
Units:
0.0 Hz
0.0/30.0 Hz
0.1 Hz
084
085
086
088 [Speed/Torque Mod]
Selects the torque reference source.
“Zero Torque” (0) - torque command = 0.
“Speed Reg” (1) - drive operates as a
speed regulator.
“Torque Reg” (2) - an external torque
reference is used for the torque
command.
Default:
Options:
1
0
1
2
3
4
5
6
“Speed Reg”
“Zero Torque”
“Speed Reg”
“Torque Reg”
“Min Torq/Spd”
“Max Torq/Spd”
“Sum Torq/Spd”
“Absolute Min”
053
“Min Torq/Spd” (3) - selects the smallest algebraic value to regulate to when the
torque reference and torque generated from the speed regulator are compared.
“Max Torq/Spd” (4) - selects the largest algebraic value when the torque reference
and the torque generated from the speed regulator are compared.
“Sum Torq/Spd” (5) - selects the sum of the torque reference and the torque
generated from the speed regulator.
“Absolute” (6) - selects the smallest absolute algebraic value to regulate to when
the torque reference and torque generated from the speed regulator are
compared.
454 [Rev Speed Limit]
Sets a limit on speed in the negative
direction, when in FVC Vector mode.
Used in bipolar mode only. A value of
zero disables this parameter and uses
[Maximum Speed] for reverse speed limit.
Default:
Min/Max:
Units:
0.0 RPM
–[Max Speed]/0.0 Hz
–[Max Speed]/0.0 RPM
0.0 Hz
0.0 RPM
File
Group
No.
Parameter Name & Description
See page 1-2 for symbol descriptions
Values
Related
FV
Vector
FV
Vector
20B-UM001.book Page 23 Thursday, June 20, 2013 1:55 PM

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 700 and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 700 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 700
CategoryDC Drives
LanguageEnglish

Related product manuals