Page #27 background imageLoading...
Page #27 background image
Programming and Parameters 1-15
MOTOR CONTROL
Motor Data
045 [Motor NP Power]
Set to the motor nameplate rated power.
Default:
Min/Max:
Units:
Based on Drive Rating
0.00/100.00
0.00/1000.00
0.01 kW/HP
See [Mtr NP Pwr Units]
046
046 [Mtr NP Pwr Units]
Selects the motor power units to be used.
Default:
Options:
0
1
Drive Rating Based
“Horsepower”
“kiloWatts”
[Mtr NP Pwr Units]
Selects the motor power units to be used.
“Convert HP” = converts all power units
to Horsepower.
“Convert kW” = converts all power units
to kilowatts.
Default:
Options:
0
1
2
3
Drive Rating Based
“Horsepower”
“kiloWatts”
“Convert HP”
“Convert kW”
047 [Motor OL Hertz]
Selects the output frequency below
which the motor operating current is
derated. The motor thermal overload will
generate a fault at lower levels of current.
Default:
Min/Max:
Units:
Motor NP Hz/3
0.0/Motor NP Hz
0.1 Hz
042
220
048 [Motor OL Factor]
Sets the operating level for the motor
overload.
Default:
Min/Max:
Units:
1.00
0.20/2.00
0.01
042
220
049 [Motor Poles]
Defines the number of poles in the motor.
Default:
Min/Max:
Units:
4
2/40
1 Pole
Torq Attributes
053 [Torque Perf Mode]
Sets the method of motor torque
production.
Default:
Options:
0
0
1
2
3
“Sensrls Vect”
“Sensrls Vect”
“SV Economize”
“Custom V/Hz”
“Fan/Pmp V/Hz”
[Motor Cntl Sel]
Sets the method of motor control used in
the drive.
Important: “FVC Vector” mode requires
autotuning of the motor, both coupled
and uncoupled to the load.
Default:
Options:
0
0
1
2
3
4
“Sensrls Vect”
“Sensrls Vect”
“SV Economize”
“Custom V/Hz”
“Fan/Pmp V/Hz”
“FVC Vector”
054 [Maximum Voltage]
Sets the highest voltage the drive will
output.
Default:
Min/Max:
Units:
Drive Rated Volts
Rated Volts x 0.25/Rated
Volts
0.1 VAC
File
Group
No.
Parameter Name & Description
See page 1-2 for symbol descriptions
Values
Related
32
Standard
Vector
Motor
FLA
OL
Factor
Operating
Level
=
x
Vector
Standard
Vector
20B-UM001.book Page 15 Thursday, June 20, 2013 1:55 PM

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 700

Questions and Answers:

Question and Answer IconNeed help?