EasyManua.ls Logo

Roger Technology B70/1DCHP - Page 69

Roger Technology B70/1DCHP
276 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
69
D
Condominium function for partial open command (PED)

Disabled. The gate opens partially in step mode: open-stop-close-stop-open...

Enabled. Partial commands are ignored during gate opening.
D 
Enabling operator present function

Disabled.

Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops when
the button is released.
D
Gate open indicator / photocell test function and “battery saving”

The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.

8LIMRHMGEXSVƽEWLIWWPS[P]HYVMRKSTIRMRKQERSIYZVIWERHMWPMXWXIEHMP][LIRXLIKEXIMWGSQTPIXIP]STIR-XƽEWLIW
quickly during closing manoeuvres.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.

Set  if the output SCMWYWIHJSVXLITLSXSGIPPXIWX7IIƼK

Set to  if the output SCMWYWIHJSVXLIƈFEXXIV]WEZMRKƉJYRGXMSR7IIƼK
When the gate is completely open or closed, the controller unit deactivates any accessories connected to terminal SC
to reduce battery consumption.

Set to  if the output SCMWYWIHJSVXLIƈFEXXIV]WEZMRKƉJYRGXMSRERHTLSXSGIPPXIWXJYRGXMSR7IIƼK

Setting deceleration during opening and closing

See chapters 14 and 15

01= the gate decelerates near the limit switch ... 05= the gate decelerates long before the limit switch.

Setting gate open limit switch constant speed approach distance
N.B.: the manoeuvre speed is set with parameter . After decelerating, the gate completes the distance to the limit
switch at constant speed.

Setting gate closed limit switch constant speed approach distance
N.B.: the manoeuvre speed is set with parameter . After decelerating, the gate completes the distance to the limit
switch at constant speed.

01= last 3 cm; 02= last 6 cm; ... 40= last 120 cm.
Approximate example: 100 cm distance = value .
 
Partial opening adjustment (%)
N.B.: This parameter is set to 50% (half of total gate travel) by default.

From 10% to 99% of total gate travel.

Type of signaling provided by COR output

STANDARD operation managed by parameter 

Contact closed if the control unit is working properly.
Contact open if central locked in alarm.

Contact closed if the control unit is powered by the mains or charged battery.
Open contact due to a fault: control unit powered by low battery (voltage level set by par.  ) or with error alert EW/2
(the control unit no longer accept commands).

Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs

Closed contact if the gate is not completely open.
Open contact if the gate is completely open.

Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.

Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate closes
automatically. The timer count restarts if a photocell is triggered.

Pause time settable from 00 to 90 s.

Pause time settable from 2 to 9 min.

Table of Contents

Other manuals for Roger Technology B70/1DCHP

Related product manuals