Test of Specification R&S M3SR Series 4100 HF Transceivers
3.15 6124.9007.82.01
NOTE:
In the case of deviations from the nominal values, perform troubleshooting according to
4 - Troubleshooting.
16 X26 Serial Connection DATA Terminal 2 /
FSK Test
16.1 Set transceiver to F1D (FSK) modulation
(default values).
Set X26.37 (PTT1_V28) to +12 VDC.
Apply +12.0 VDC to X26.33 (TXD2).
By using the digital multimeter, verify DC volt-
age at X26.19.
> +3.0 VDC
Apply -12.0 VDC to X26.33 (TXD2).
Verify DC voltage at X26.19. < -3.0 VDC
Release X26.37 (PTT1_V28) to open.
17 X5011/X5012 GS4102 NMEA/DSC Inter-
face Test (optional)
17.1 Connect a DSC Controller to the NMEA
Interface and check if control of transceiver is
taken over in transceiver Maintenance Menu
MTC#3.
Control of transceiver is taken over.
No. Activity Nominal Value