46
Settings
Viewing Information for the TD-50 Itself
(INFO)
Here’s how to view information for the TD-50 unit itself, such as its
program version.
1. In the SETUP MENU 2 screen (p. 42), press the [F3] (INFO)
button.
The information screen appears.
2. Press a [F1] (PROGRAM)–[F4] (DIGITAL) button to select
the item that you want to edit.
Button Explanation
[F1] (PROGRAM)
button
Displays the program version.
[F2] (SAMPLE) button
Displays the number of loaded user samples and
the remaining amount of space for user samples in
user memory.
[F3] (SD CARD) button
Displays the number of backup data, kit backup
data, and recorded data that are saved on the SD
card.
[F4] (DIGITAL) button
Displays the program version of the digital
connection compatible pads that are connected
to the TD-50.
The FUNC button of the selected pad is blinking.
3. Press the [KIT] button to return to the DRUM KIT screen.
Restoring the Factory Settings
(FACTORY RESET)
The “Factory Reset” operation returns all data and settings stored in
the TD-50 to their factory-set condition.
NOTE
When you execute this operation, all data and settings in the TD-50
will be lost. Before you proceed, you should save any important
data and settings to your SD card (p. 39).
1. In the SETUP MENU 3 screen (p. 42), press the [F1]
(FACTORY RESET) button.
The FACTORY RESET screen appears.
MEMO
If you want all user samples to also be returned to their factory-
set state, use the [–] [+] buttons or the dial to add a check mark
to “Reset with User Sample.” All user samples in user memory are
overwritten by the factory-set data.
2. Press the [F5] (FACTORY RESET) button.
A conrmation message appears.
If you decide to cancel, select “CANCEL” and press the [ENTER]
button.
3. Select “OK” and press the [ENTER] button.